DFG-RS5
• |
Interchangeable Force and Torque Sensors
|
• |
High Speed 7000 Hz Sampling Rate
|
• |
Selectable Units of Measure
|
• |
Load Cells Available in Ranges from 0.25 to 10,000 lb
|
• |
Torque Sensors for 10 oz-in to 100 lb-in Ranges
|
• |
Calibration Data Stored in Sensor
|
• |
USB, RS232, Mitutoyo and Analog Outputs
|
• |
Programmable Setpoints with Indicators and Outputs
|
• |
Large Backlit Graphics Display
|
• |
Live Load Bar Graph with Set Point Markers
|
• |
Peak Readings and Set Points Always Displayed
|
The DFG-RS5 is a high performance digital indicator that works with a wide variety of plug and play force and torque sensors. All calibration and configuration data is stored in the sensors smart connector instead of the indicator making the sensors truly interchangeable. In addition all of the remote sensors are also fully compatible with the DFG-RS3 basic force/torque indicators. A variety of interchangeable force and torque sensors are available for use with the DFG-RS3 series. Sensors are available in a range of capacities from 0.25 to 10,000 pounds force for load cells and 10 oz-in to 100 lb-in for torque sensors. In addition to the pre-calibrated sensors the DFG-RSA programmable adaptor allows the end user to calibrate most bridge type force or torque sensor with a 1 to 3 mV/V full scale output to work with the DFG-RS5. The DFG-RS5 also shares menu structure and most specifications with the DFG55 force gauges. It’s fast 7000 Hz sampling rate produces accurate results even for quick action tests. It also has an average mode that addresses the need to record the average load over time and an on board data memory for up to 1000 readings. A backlit graphic LCD displays large characters and a menu is available to access the gauges features and configurable parameters. Units also have a USB output for data collection and setpoint indicators for pass-fail testing.
SPECIFICATIONS Accuracy: 0.1% of full scale ±1 digit + sensor Power: Rechargeable battery or AC using adapter (batteries and adapter included) Battery Life: Up to 7 hours continuous use with backlight on or 24 hours with backlight off Low Battery: Multi-step low battery indicator is displayed, gauge shuts off automatically when power is too low Configurable Settings: Digital filters, outputs, automatic shutoff, default settings, averaging mode, external trigger, passwords, key tones, audio alarms, backlight, calibration Outputs: USB/RS232 Output: Configurable to 115,200 baud Mitutoyo (Digimatic): Serial BCD suitable for all Mitutoyo SPC compatible devices DFG-RSA smaller than actual size. Calibrates remote sensor to meter. Analog: ±1 Vdc, ±2% full scale accuracy General Purpose: 3 open drain outputs, 1 input Set Points: 3 open drain lines Operating Temperature: 4 to 38°C (40 to 100°F) Humidity: 96% RH non-condensing Dimensions: 149.4 H x 64.3 W x 33.6 mm D (5.88 x 2.53 x 1.32") Weight: 0.3 kg (0.7 lb) SENSOR COMMON SPECIFICATIONS Operating Temperature: 5 to 38°C (40 to 100°F) Operating Humidity: 96% non-condensing maximum LOAD CELLS Safe Overload: 150% of full scale (200% for RLC03-025, RLC03-2 and RLC04 series) TORQUE SENSORS Safe Overload: 150% of full scale (300% for RTQ50-10Z, RTQ50-50Z) Chuck Opening: RTQ50-10Z and RTQ50-50Z – 0.062 to 0.375" RTQ50-12, RTQ50-100 – 0.078 to 0.5" |